Latest Papers

ASME Journal of Mechanisms and Robotics

  • Investigation on a Class of 2D Profile Amplified Stroke Dielectric Elastomer Actuators
    on September 24, 2024 at 12:00 am

    AbstractDielectric elastomer actuators (DEAs) have been widely studied in soft robotics due to their muscle-like movements. Linear DEAs are typically tensioned using compression springs with positive stiffness or weights directly attached to the flexible film of the DEA. In this paper, a novel class of 2D profile linear DEAs (butterfly- and X-shaped linear DEAs) with compact structure is introduced, which, employing negative-stiffness mechanisms, can largely increase the stroke of the actuators. Then, a dynamic model of the proposed amplified-stroke linear DEAs (ASL-DEAs) is developed and used to predict the actuator stroke. The fabrication process of linear DEAs is presented. This, using compliant joints, 3D-printed links, and dielectric elastomer, allows for rapid and affordable production. The experimental validation of the butterfly- and X-shaped linear DEAs proved capable of increasing the stroke up to 32.7% and 24.0%, respectively, compared with the conventional design employing springs and constant weights. Finally, the dynamic model is validated against the experimental data of stroke amplitude and output force; errors smaller than 10.5% for a large stroke amplitude (60% of maximum stroke) and 10.5% on the output force are observed.

Geometric Error Calibration of XYZ -3RPS Hybrid Kinematic Machine via Binocular Vision

Abstract

To improve the motion accuracy of an XYZ-3RPS hybrid kinematic machine (HKM), a geometric error calibration method via binocular vision measurement is studied. First, to separately calibrate the series kinematic mechanisms (SKMs) and parallel kinematic mechanisms (PKMs), the geometric error identification equations (GEIEs) of the XYZ SKM and 3RPS PKM are derived, respectively. By analyzing the different influence principles of the geometric errors on the position and attitude of the 3RPS PKM, a constraint function is added to the GEIE of the PKM to improve the calculation accuracy. Moreover, the geometric error compensation strategy is based on the structural characteristics of the XYZ-3RPS HKM. In addition, based on the principle of binocular vision measurement, two calibration plates, called dynamic and static calibration plates, are designed as markers to define the coordinate systems, enabling the acquisition of full positions and attitudes. Furthermore, a marker transformation method and an in-situ adjustment method are designed to determine the positions and attitudes of the HKM required for calibration such that the marker is always at the center of the field of view of the camera to improve measurement accuracy. Finally, the effectiveness of the calibration method is verified through prototype experiments.

Read More

Journal of Mechanisms and Robotics Open Issues